- Programmable Features By Personal Computer Or At Factory
- Call Sign
- Up to 50 character call sign, "-" and "/"
- Call sign proceeded by DE (from) for repeaters
- Operation Modes
- 1 Identifies after each time period
- 2 Identifies after each transmission
- 3 Identifies one time period after beginning of a transmission
- 4 Identifies at the beginning of a transmission and again one time
period after its beginning
- Monitor Release Delay Timer:
- 3 seconds, programmable from 0-19 seconds
- Interval Timer (time period):
- 15 Minutes, programmable 0-63 minutes
- Morse Code Speed:
- 24 Word/Minute, programmable 10 to 40
- Tone Frequency:
- 1080 Hz, programmable 690 to 2000 Hz
- Monitor Inputs
- Receiver (Rx) COR Monitor
- Switch set to active low or active high
- Transmitter (Tx) Keying Monitor
- Active low. Usually controlled by push to talk closure. This
terminal starts interval timer in modes 3 & 4
- RX And TX Monitor Loading
- 1 mA max, at 0 VDC, 0 mA when above +5 VDC
- RX And TX Monitor Levels
- Digital low = 0 to +1.2 VDC
- Digital hi = +3.5 to +75 VDC
- Audio Output
- 1000 ohm +/- 20% impedance
- Modified Squarewave
- Output Noise, 30db below rated output
- Output Level, variable from -25 to -3 DBM
- Test switch, transmit indicator
- Options Available
- PC programming cable and software
- 120 VAC wall transformer
- Factory programming
- Toneless CW pulsed carrier ID
- Operates on 8-16 VDC/VAC 100 mA
- Size: 3.3" wide x 2.4" high x 1.2" deep
- All features and operation modes comply with FCC regulations
|